RE 18305-09/12.13
1/10
DVI0105
4/3 - 4/2 Directional valve with
solenoid actuation
L511… (LC1-DZ)
Size NG6 ISO 4401-03 CETOP RP121 H-03 (CETOP 3)
Series 00
Maximum operating pressure 310 bar
[4500 psi]
Maximum flow 50 l/min
[13.2 gpm]
- Valve elements with solenoid operated directional
spool.
- Control spools operated by solenoids with removable
coils.
- In the de-energized condition, the control spool is held
in the central position by return springs.
- Wet pin tubes for DC coils, with push rod for
mechanical override; nickel plated surface.
- Coils can be rotated 360° around the tube; they can
be energized by AC current through special connectors
with rectifier (RAC).
- Manual override (push-button or screw type) available
as option.
Summary General specifications
Description Page
General specifications 1
Ordering details 2
Spool variants 3
Principles of operation, cross section 4
Technical Data 4
Δp-Q
v
characteristic curves 6
Performance limits 6
External Dimensions and Fittings 7
Electric connections 9
LC1-DZ RE 18305-09/12.13
2/10
Bosch Rexroth Oil Control S.p.A.
L 5 1 1 1 _ _ _ _ _ _ _ _ _ _
Ordering Details
Voltage supply
00 =
Without coil
OB =
12V DC
AD =
13V DC
OC =
24V DC
AC =
27V DC
OD =
48V DC
OE =
110V DC
OV =
(21.5 DC) 24V AC
OW =
(98 DC) 110V AC
OZ =
(207 DC) 230V AC
07 03 01 00
Available
connections
Family
Directional Valves
Cetop 3
Type
Size 6
Coil
C45
Circuit
4/3 operated on both sides A and B = _ 2 _ _
4/2 operated on side A only = _ 3 _ _
4/2 operated on side B only = _ 4 _ _
Options
_ _ = Lever type manual override
2)
00 = Standard
0P = Push-button type manual override
0F = Screw type manual override
Electric connections
00 = Without coils
01
**= With coils, without mating connector DIN EN
175301-803
03 = With coils, with bi-directional diode,
without mating connector vertical Amp-Junior
07 = With coils, with bi-directional diode,
without mating connector DT04-2P
_ _ = Special
RE 18305-09/12.13 LC1-DZ
Bosch Rexroth Oil Control S.p.A.
3/10
AB
_ 2 _ _
P
T
a0b
ab
AB
_ 2 _ _
P
T
ab
ab
AB
_ 3 _ _
P
T
a0
a
AB
_ 4 _ _
P
T
0b
b
AB
_ 5 _ _
P
T
ab
a
b
=A201
=B201
=C201
=D201
=E201
=F201
=G201
=K201
=U201
=E2R1
=G209
=K209
=A301
=B301
=C301
=D301
=E301
=K301
=T301
=X301
=U369
=A401
=B401
=C401
=D401
=E401
=K401
=T409
=X401
=L201
=M201
=N201
=L501
=N501
=A581
=M501
=A361
=B361
=C361
=D361
=E361
=N301
=T361
=Y301
=A471
=B471
=C471
=D471
=E471
=N401
=T479
=Y401
Spool variants
LC1-DZ RE 18305-09/12.13
4/10
Bosch Rexroth Oil Control S.p.A.
675 4 12 456733
Technical Data (for applications with different specifications consult us)
General
Valve element with 2 solenoids kg
[lbs]
1.82
[4.0]
Valve element with 1 solenoid kg
[lbs]
1.33
[2.9]
Valve element with 2 solenoids,
with lever type emergency
kg
[lbs]
2.1
[4.6]
Valve element with 1 solenoid,
with lever type emergency
kg
[lbs]
1.6
[3.5]
Ambient Temperature °C
[°F]
–20....+50
[-4....+122]
(NBR seals)
Hydraulic
Maximum pressure at P, A and B ports bar
[psi]
310
[4500]
Maximum pressure at T bar
[psi]
250
[3625]
Max pressure,
with lever type emergency at T
bar
[psi]
200
[2900]
Maximum inlet flow l/min
[gpm]
50
[13.2]
Hydraulic fluid
General properties: it must have physical
lubricating and chemical properties suitable
for use in hydraulic systems such as, for
example:
Mineral oil based hydraulic fluids HL (DIN 51524 part 1).
Mineral oil based hydraulic fluids HLP (DIN 51524 part 2).
For use of environmentally acceptable fluids (vegetable or polyglycol base)
please consult us.
Fluid Temperature °C
[°F]
–20....+80
[-68....+176]
(NBR seals)
Permissible degree of fluid contamination
ISO 4572: β
x
75 X=12...15
ISO 4406: class 20/18/15
NAS 1638: class 9
Viscosity range mm
2
/s 5....420
Principles of operation, cross section
The sandwich plate design directional valve elements
L511… are compact direct operated solenoid valves
which control the start, the stop and the direction
of the oil flow. These elements basically consist of a
stackable housing (1) with a control spool (2), one or
two solenoids (5), and one or two return springs (4).
When energized, the force of the solenoid (5) pushes
the control spool (2) from its neutral-central position
“0” to the required end position “a” or “b”, and the
required flow from P to A (with B to T), or P to B (with
A to T) is achieved. Once the solenoid is de-energized,
the return spring (4) pushes the spool thrust washer
(3) back against the housing and the spool returns in
its neutral-central position.
Each coil is fastened to the solenoid tube by a ring nut
(6). A pin (7) allows to push the spool (2) in emergency
conditions, when the solenoid cannot be energized, like
in case of voltage shortage.
RE 18305-09/12.13 LC1-DZ
Bosch Rexroth Oil Control S.p.A.
5/10
Electrical
Voltage type DC (AC only with RAC connection)
Voltage tolerance (nominal voltage) % -10 .... +10
Duty Continuous, with ambient temperature 50°C
[122°F]
Coil wire temperature not to be exceeded °C
[°F]
150
[302]
Insulation class H
Compliance with
Low Voltage Directive LVD 73/23/EC (2006/95/EC),
2004/108/EC
Coil weight with connection EN 175301-803 kg
[lbs]
0.335
[0.74]
Voltage V
12 13 24 27 48 110
24
+
RAC
(21,5)
110
+
RAC
(98)
230
+
RAC
(207)
Voltage type
DC DC DC DC DC DC DC DC DC
Power consumption W
33 31 33 33 33 35 33 33 35
Current (nominal at 20°C
[68°F]
)
A
2.8 2.3 1.4 1.2 0.7 0.32 1.6 0.34 0.16
Resistance (nominal at 20°C
[68°F]
)
Ω
4.24 5.42 17 21.8 69.8 341.8 13.6 285 1229
Voltage (V) Connector type Code Marking Coil Mat no.
=OB 01
12 DC
EN 175301-803
(Ex. DIN 43650)
C4501 12DC 12 DC R933000026
=OB 03
12 DC AMP JUNIOR C4503 12DC 12 DC R933000027
=OB 07
12 DC DEUTSCH DT 04-2P C4507 12DC 12 DC R933000030
=AD 01
13 DC
EN 175301-803
(Ex. DIN 43650)
C4501 13DC 13 DC R933000028
=AD 03
13 DC AMP JUNIOR C4503 13DC 13 DC R933000029
=AD 07
13 DC DEUTSCH DT 04-2P C4507 13DC 13 DC R933000031
=OC 01
24 DC
EN 175301-803
(Ex. DIN 43650)
C4501 24DC 24 DC R933000034
=OC 03
24 DC AMP JUNIOR C4503 24DC 24 DC R933003630
=OC 07
24 DC DEUTSCH DT 04-2P C4507 24DC 24 DC R933000032
=AC 01
27 DC
EN 175301-803
(Ex. DIN 43650)
C4501 27DC 27 DC R933000035
=AC 03
27 DC AMP JUNIOR C4503 27DC 27 DC R933000036
=AC 07
27 DC DEUTSCH DT 04-2P C4507 27DC 27 DC R933000033
=OD 01
48 DC
EN 175301-803
(Ex. DIN 43650)
C4501 48DC 48 DC R933000037
=OE 01
110 DC
EN 175301-803
(Ex. DIN 43650)
C4501 110DC 110 DC R933000040
=OV 01
24 RAC
EN 175301-803
(Ex. DIN 43650)
C4501 21.5DC 21.5 DC R933000038
=OW 01
110 RAC
EN 175301-803
(Ex. DIN 43650)
C4501 98DC 98 DC R933000039
=OZ 01
230 RAC
EN 175301-803
(Ex. DIN 43650)
C4501 207DC 207 DC R933000041
LC1-DZ RE 18305-09/12.13
6/10
Bosch Rexroth Oil Control S.p.A.
18
15
12
9
6
3
0
0 5 10 15 20 25 30 35 40 45 50l/min
0 1 2 3 4 5 6 7 8 9 10 11 12 13 13,2 gpm
260
250
200
150
100
50
0
bar
350
300
250
200
150
100
50
0
0 5 10 15 20 25 30 35 40 45 50 l/min
0 1 2 3 4 5 6 7 8 9 10 11 12 1313.2 gpm
psi
5000
4000
3000
2000
1000
0
ΔP barΔP psi
0 1 2 3 4 5 6 l/min
0 0.3 0.6 0.9 1.2 1.6 gpm
bar
60
50
40
30
20
10
0
psi
900
750
600
450
300
150
0
PRESSURE-Δp
FLOW-Q
PRESSURE-p
FLOW-Q
PRESSURE-p
FLOW-Q
Characteristic curves
Measured with hydraulic fluid ISO-VG32 at 45° ± 5° C
[113° ± 9° F]
; ambient temperature 20° C
[68° F]
.
Performances limits
Minimum flow for efficiency of LS control
RE 18305-09/12.13 LC1-DZ
Bosch Rexroth Oil Control S.p.A.
7/10
External Dimensions and Fittings
1 Solenoid tube Ø 19 mm
[0.75 inch].
2 Plug for two position version
3 Ring nut for coil locking (Ø 26.5 mm);
torque 3-4Nm
[2.2-3 ft-lb].
4 Flange specifications Cetop3
5 Four threaded holes M5 for fitting a secondary flangeable
element. Bolts M5 with recommended strength class
DIN 8.8: torque 5-6 Nm
[3.6-4.4 ft-lb].
6 O-Rings for P-T-A-B ports.
7 Clearance needed for connector removal.
8 Identification label.
9 Optional push-button manual override, 0P type, for
spool opening: it is pressure stuck to the ring nut for coil
locking. Mat no. R933000043.
10 Optional screw type manual override, 0F type, for spool
opening: it is screwed (torque 6-7
[4.4-5.2 ftlb]
) to the
tube as replacement of the coil ring nut.
Mat no. R933007215.
LC1-DZ RE 18305-09/12.13
8/10
Bosch Rexroth Oil Control S.p.A.
External Dimensions and Fittings
1 Ordering Details: HA (if fitted to side A)
or HB (if fitted to side B).
2 Ordering Details: VA (if fitted to side A)
or VB (if fitted to side B).
3 Ordering Details: H1 (if fitted to side A)
or H9 (if fitted to side B).
4 Ordering Details: V1 (if fitted to side A)
or V9 (if fitted to side B).
5 Ordering Details: XA (if fitted to side A)
or XB (if fitted to side B).
6 Ordering Details: X1 (if fitted to side A)
or X9 (if fitted to side B).
RE 18305-09/12.13 LC1-DZ
Bosch Rexroth Oil Control S.p.A.
9/10
=00 =01
=03 =07
Electric connections
Protection class: IP 65 with female connector
properly fitted (see drawing).
Protection class: IP 69 K with female connector
properly fitted (see drawing).
LC1-DZ RE 18305-09/12.13
10/10
Bosch Rexroth Oil Control S.p.A.
Bosch Rexroth Oil Control S.p.A.
Oleodinamica LC Division
Via Artigianale Sedrio, 12
42030 Vezzano sul Crostolo
Reggio Emilia - Italy
Tel. +39 0522 601 801
Fax +39 0522 606 226 / 601 802
compact-directional-valves@oilcontrol.com
www.boschrexroth.com
© This document, as well as the data, specifications and other information
set forth in it, are the exclusive property of Bosch Rexroth Oil Control S.p.a.. It
may not be reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements
concerning a certain condition or suitability for a certain application can be
derived from our information. The information given does not release the user
from the obligation of own judgment and verification. It must be remembered
that our products are subject to a natural process of wear and aging.
Subject to change.