LC1-DZ RE 18305-09/12.13
4/10
Bosch Rexroth Oil Control S.p.A.
675 4 12 456733
Technical Data (for applications with different specifications consult us)
General
Valve element with 2 solenoids kg
[lbs]
1.82
[4.0]
Valve element with 1 solenoid kg
[lbs]
1.33
[2.9]
Valve element with 2 solenoids,
with lever type emergency
kg
[lbs]
2.1
[4.6]
Valve element with 1 solenoid,
with lever type emergency
kg
[lbs]
1.6
[3.5]
Ambient Temperature °C
[°F]
–20....+50
[-4....+122]
(NBR seals)
Hydraulic
Maximum pressure at P, A and B ports bar
[psi]
310
[4500]
Maximum pressure at T bar
[psi]
250
[3625]
Max pressure,
with lever type emergency at T
bar
[psi]
200
[2900]
Maximum inlet flow l/min
[gpm]
50
[13.2]
Hydraulic fluid
General properties: it must have physical
lubricating and chemical properties suitable
for use in hydraulic systems such as, for
example:
Mineral oil based hydraulic fluids HL (DIN 51524 part 1).
Mineral oil based hydraulic fluids HLP (DIN 51524 part 2).
For use of environmentally acceptable fluids (vegetable or polyglycol base)
please consult us.
Fluid Temperature °C
[°F]
–20....+80
[-68....+176]
(NBR seals)
Permissible degree of fluid contamination
ISO 4572: β
x
≥75 X=12...15
ISO 4406: class 20/18/15
NAS 1638: class 9
Viscosity range mm
2
/s 5....420
Principles of operation, cross section
The sandwich plate design directional valve elements
L511… are compact direct operated solenoid valves
which control the start, the stop and the direction
of the oil flow. These elements basically consist of a
stackable housing (1) with a control spool (2), one or
two solenoids (5), and one or two return springs (4).
When energized, the force of the solenoid (5) pushes
the control spool (2) from its neutral-central position
“0” to the required end position “a” or “b”, and the
required flow from P to A (with B to T), or P to B (with
A to T) is achieved. Once the solenoid is de-energized,
the return spring (4) pushes the spool thrust washer
(3) back against the housing and the spool returns in
its neutral-central position.
Each coil is fastened to the solenoid tube by a ring nut
(6). A pin (7) allows to push the spool (2) in emergency
conditions, when the solenoid cannot be energized, like
in case of voltage shortage.